149 research outputs found

    Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration

    Get PDF
    (1) To determine the optimal administration site and dose of indocyanine green (ICG) for blood volume measurement using pulse spectrophotometry, (2) to assess the variation in repeated blood volume measurements for patients after subarachnoid hemorrhage and (3) to evaluate the safety and efficacy of this technique in patients who were treated for an intracranial aneurysm. Four repeated measurements of blood volume (BV) were performed in random order of bolus dose (10 mg or 25 mg ICG) and venous administration site (peripheral or central) in eight patients admitted for treatment of an intracranial aneurysm. Another five patients with subarachnoid hemorrhage underwent three repeated BV measurements with 25 mg ICG at the same administration site to assess the coefficient of variation. The mean +/- SD in BV was 4.38 +/- 0.88 l (n = 25) and 4.69 +/- 1.11 l (n = 26) for 10 mg and 25 mg ICG, respectively. The mean +/- SD in BV was 4.59 +/- 1.15 l (n = 26) and 4.48 +/- 0.86 l (n = 25) for central and peripheral administration, respectively. No significant difference was found. The coefficient of variance of BV measurement with 25 mg of ICG was 7.5% (95% CI: 3-12%). There is no significant difference between intravenous administration of either 10 or 25 mg ICG, and this can be injected through either a peripheral or central venous catheter. The 7.5% coefficient of variation in BV measurements determines the detectable differences using ICG pulse spectrophotometr

    Dynamic and volumetric variables reliably predict fluid responsiveness in a porcine model with pleural effusion

    Get PDF
    Background: The ability of stroke volume variation (SVV), pulse pressure variation (PPV) and global end-diastolic volume (GEDV) for prediction of fluid responsiveness in presence of pleural effusion is unknown. The aim of the present study was to challenge the ability of SVV, PPV and GEDV to predict fluid responsiveness in a porcine model with pleural effusions. Methods: Pigs were studied at baseline and after fluid loading with 8 ml kg−1 6% hydroxyethyl starch. After withdrawal of 8 ml kg−1 blood and induction of pleural effusion up to 50 ml kg−1 on either side, measurements at baseline and after fluid loading were repeated. Cardiac output, stroke volume, central venous pressure (CVP) and pulmonary occlusion pressure (PAOP) were obtained by pulmonary thermodilution, whereas GEDV was determined by transpulmonary thermodilution. SVV and PPV were monitored continuously by pulse contour analysis. Results: Pleural effusion was associated with significant changes in lung compliance, peak airway pressure and stroke volume in both responders and non-responders. At baseline, SVV, PPV and GEDV reliably predicted fluid responsiveness (area under the curve 0.85 (p<0.001), 0.88 (p<0.001), 0.77 (p = 0.007). After induction of pleural effusion the ability of SVV, PPV and GEDV to predict fluid responsiveness was well preserved and also PAOP was predictive. Threshold values for SVV and PPV increased in presence of pleural effusion. Conclusions: In this porcine model, bilateral pleural effusion did not affect the ability of SVV, PPV and GEDV to predict fluid responsiveness

    Extravascular Lung Water Correlates Multiorgan Dysfunction Syndrome and Mortality in Sepsis

    Get PDF
    BACKGROUND: This study was designated to investigate whether increased extravascular lung water index (EVLWI) may correlate multiple organ dysfunction syndrome (MODS) and mortality in sepsis. METHODS: We designed a prospective cohort study in an intensive care unit of a tertiary care hospital. Sixty-seven patients with severe sepsis were included. Data were used to determine an association between EVLWI and the development of MODS and mortality. These connections were determined by the multiple logistic regression, plotting the receiver operating characteristic (ROC) curve and by Spearman test. RESULTS: EVLWI levels were higher in MODS patients on day 1 (median (IQR), 18(12.8-23.9) ml/kg, n = 38, p<0.0001) than in those without (median (IQR), 12.4 (7.9-16.3) ml/kg, n = 29) and day 3 (median (IQR), 17.8 (11.2-22.8) ml/kg, n = 29, p = 0.004) than in those without (median (IQR), 12.4 (8.0-16.3) ml/kg, n = 29). EVLWI was used as an independent predictor of the development of MODS (odds ratio, 1.6; p = 0.005; 95% confidence interval, 1.2∼2.2) during ICU stay. The area under the ROC curve showed that EVLWI levels could predict MODS (0.866) and mortality (0.881) during ICU stay. Meanwhile, the higher of SOFA score, the more EVLWI was found on day 1 (r = 0.7041, p<0.0001) and day 3 (r = 0.7732, p<0.0001). CONCLUSIONS: Increased EVLWI levels correlates development of MODS and mortality during the patients' ICU stay. Further more, the potential of novel treatment in severe sepsis with lung injury may develop

    Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine.

    Get PDF
    OBJECTIVE: Circulatory shock is a life-threatening syndrome resulting in multiorgan failure and a high mortality rate. The aim of this consensus is to provide support to the bedside clinician regarding the diagnosis, management and monitoring of shock. METHODS: The European Society of Intensive Care Medicine invited 12 experts to form a Task Force to update a previous consensus (Antonelli et al.: Intensive Care Med 33:575-590, 2007). The same five questions addressed in the earlier consensus were used as the outline for the literature search and review, with the aim of the Task Force to produce statements based on the available literature and evidence. These questions were: (1) What are the epidemiologic and pathophysiologic features of shock in the intensive care unit ? (2) Should we monitor preload and fluid responsiveness in shock ? (3) How and when should we monitor stroke volume or cardiac output in shock ? (4) What markers of the regional and microcirculation can be monitored, and how can cellular function be assessed in shock ? (5) What is the evidence for using hemodynamic monitoring to direct therapy in shock ? Four types of statements were used: definition, recommendation, best practice and statement of fact. RESULTS: Forty-four statements were made. The main new statements include: (1) statements on individualizing blood pressure targets; (2) statements on the assessment and prediction of fluid responsiveness; (3) statements on the use of echocardiography and hemodynamic monitoring. CONCLUSIONS: This consensus provides 44 statements that can be used at the bedside to diagnose, treat and monitor patients with shock

    Missing effects of zinc in a porcine model of recurrent endotoxemia

    Get PDF
    BACKGROUND: Chronic human sepsis often is characterised by the compensatory anti-inflammatory response syndrome (CARS). During CARS, anti-inflammatory cytokines depress the inflammatory response leading to secondary and opportunistic infections. Proved in vitro as well as in vivo, zinc's pro-inflammatory effect might overcome this depression. METHODS: We used the model of porcine LPS-induced endotoxemia established by Klosterhalfen et al. 10 pigs were divided into two groups (n = 5). Endotoxemia was induced by recurrent intravenous LPS-application (1.0 μg/kg E. coli WO 111:B4) at hours 0, 5, and 12. At hour 10, each group received an intravenous treatment (group I = saline, group II = 5.0 mg/kg elementary zinc). Monitoring included hemodynamics, blood gas analysis, and the thermal dilution technique for the measurement of extravascular lung water and intrapulmonary shunt. Plasma concentrations of IL-6 and TNF-alpha were measured by ELISA. Morphology included weight of the lungs, width of the alveolar septae, and rate of paracentral liver necrosis. RESULTS: Zinc's application only trended to partly improve the pulmonary function. Compared to saline, significant differences were very rare. IL-6 and TNF-alpha were predominately measured higher in the zinc group. Again, significance was only reached sporadically. Hemodynamics and morphology revealed no significant differences at all. CONCLUSION: The application of zinc in this model of recurrent endotoxemia is feasible and without harmful effects. However, a protection or restoration of clinical relevance is not evident in our setting. The pulmonary function just trends to improve, cytokine liberation is only partly activated, hemodynamics and morphology were not influenced. Further pre-clinical studies have to define zinc's role as a therapeutic tool during CARS
    • …
    corecore